Fujitsu Standard Series AUXG18KRLB/AUYG18KBTB 5.2kw Circular Flow Cassette Air Conditioning System.

The Fujitsu Circular Flow Cassette ranges from 5kw up to 13.4kw and is the perfect choice of systems for areas such as home gyms, small/large offices and even small warehouses. They have a classic 900mm x 900mm design and incorporate plenty of great features, one of which is the individual louvre movement feature, which allows each of the louvres to be controlled individually, to provide a much more comfortable airflow.


Indoor unit, Remote controller, Outdoor unit


Unit Features:
  • Unique Circular Flow Design
  • Individual Louvre Control
  • Compact and Lightweight Outdoor Unit
  • Low ambient operation
  • Various Cassette Grille

Economy mode: A thermostat setting is adjusted automatically according to the room temperature to avoid unnecessary cooling or heating.Room temperature set point limitation : The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.Set temperature auto return : The setting temperature automatically returns to the previously set temperature.Auto changeover: The unit automatically switches between heating and cooling operations based on the set temperature and room temperature.Vertical swing louver: The louver automatically swings up and down.Automatic fan speed: Microprocessor automatically adjusts the fan speed and airflow according to changes in room temperature.Auto restart: The unit automatically restarts in the previous operation mode when power returns after an outage.Connectable fresh air duct : Outside air can be introduced by attaching field supplied duct to fresh air knockout and optional part.Connectable distributing duct : Systems are capable of attaching field-supplied branch ducts distributing the airflow.Individual airflow direction control : Each louver of 4-way Cassette type can be controlled individually and provides comfortable airflow.Auto off timer : Automatically stops operation when a fixed time has elapsed from the start of operation.Weekly timer : Different ON-OFF times can be set for each day.Filter sign : Indicates the filter cleaning period by lamp.External ON/OFF inputDrain pump equipped as standardBlue fin

Specification:
 
Fujitsu Compact Cassette System   AUYG18KRLB AUYG22KRLB AUYG24KRLB AUYG30KRLB AUYG36KRLB
Nominal Cooling Capacity (Range) KW 5.2 (0.9-5.9) 6.0 (0.9-6.7) 6.8 (0.9-8.0) 8.5 (2.8-10.0) 9.5 (2.8-11.2)
UK Cooling (Total/Sensible) KW 5.01/4.03 5.85/4.30 6.63/4.74 8.08/5.77 9.03/6.49
Nominal Heating Capacity (Range) KW 6.0 (0.9-7.5) 7.0 (0.9-8.0) 7.5 (0.9-9.1) 10.0 (2.7-11.2) 10.8 (2.7-12.7)
UK Heating KW 6.64 6.91 7.66 9.63 10.92
EER Cooling / COP Heating   3.82 / 3.80 3.51 / 3.85 3.60 / 3.95 3.49 / 3.98 3.26 / 4.40
SEER / Energy Efficiency Class - Cooling   7.00 / A++ 7.00 / A++ 6.60 / A++ 6.70 / A++ 6.55 / A++
SCOP / Energy Efficiency Class - Heating   4.30 / A+ 4.40 / A+ 4.20 / A+ 4.30 / A+ 4.30 / A+
Annual Energy Consumption Cool / Heat kwh/a 260 / 1431 300 / 1527 360 / 1999 442 / 2601 507 / 2828
Pdesign Cooling / Heating (-10 Degrees) KW 5.2 / 4.4 6.0 / 4.8 6.8 / 6.0 8.5 / 8.0 9.5 / 8.7
Indoor Dimensions (HxWxD) mm 246x840x840 246x840x840 246x840x840 288x840x840 288x840x840
Outdoor Dimensions (HxWxD) mm 632x799x290 632x799x290 716x820x315 788x940x320 788x940x320
Weight (Indoor / Outdoor) KG 23.0 / 36.0 23.0 / 38.0 24.0 / 42.0 26.0 / 52.0 29.0 / 52.0
Sound pressure Level Indoor - Min / Max DB(A) 28 / 33 28 / 33 29 / 35 33 / 40 34 / 44
Pipe Size (Liquid - Gas) mm 1/4" - 1/2" 1/4" - 1/2" 1/4" - 1/2" 3/8" - 5/8" 3/8" - 5/8"
Mix / Max Pipe Length (Precharge) - Height Difference M 3 - 20 (15) / 15 3 - 25 (15) / 20 3 - 25 (20) / 20 3 - 30 (30) / 30 3 - 30 (30) / 30
Additional Refrigerant charge g/m 20 20 20 40 40
Ref Type (Global Warming Potential)   R32 (675) R32 (675) R32 (675) R32 (675) R32 (675)
Refrigerant Charge kg / CO2eq-T   1.02 / 0.689 1.25 / 0.844 1.25 / 0.844 1.90 / 1.283 1.90 / 1.283
Power Source / Suggested Fuse Size  
1PH-230V-50Hz / 16
 
1PH-230V-50Hz / 16 1PH-230V-50Hz / 16 1PH-230V-50Hz / 25 1PH-230V-50Hz / 25

Prices Include VAT and Delivery to a UK address, excluding Highlands

We know that choosing a system can be a challenge. We try to include all the relevant information to make it easy for the customer to self check out but we do have an expert team on hand if you need any assistance.

Please feel free to call.

  • Portable units
  • Portable units
Air conditioning
Members
Please click here to sign in or register.
Customers
Info
Aircon 247
4.8 /5 based on 46 Customer reviews

Sunbelt Rentals Limited
102 Dalton Ave
Birchwood Park
Birchwood
Warrington
WA3 6YE
t/a www.aircon247.com

03700500760